How to write a web design contract: 12 clauses, in order

On this page
To write a web design contract, map the project's four stress points (kickoff, the build, launch, and the weeks after launch) and write one clause for each thing that can go wrong at each point. Those clauses cover what you build, what the client supplies and by when, how many revision rounds are included, when money is due, who owns which files, and how either side can leave. Attach the scope and brief as exhibits, set response windows in business days, and have a lawyer in your jurisdiction review the draft before the first client signs it.
This article is general information about structure and wording, not legal advice. What a contract must contain, and whether a clause is enforceable, differs between countries and states, and the boilerplate section is where professional review earns its fee.
Write the contract backwards from the argument
Most templates order clauses by habit: parties, services, fees, then a long tail of legal boilerplate. That order makes it easy to sign and hard to use. When a project goes sideways, nobody rereads the contract from the top. They search for the one clause that answers today's argument.
So sort the clauses by the moment they get tested. Twelve clauses cover many of the disputes that come up in a typical website project. Seven of them get tested before launch, which is why a contract that only covers fees and ownership is half-finished.
| # | Stage | Clause | The argument it settles |
|---|---|---|---|
| 1 | Kickoff | Parties and project summary | Who is the client, and who on their side can approve? |
| 2 | Kickoff | Scope and deliverables (exhibit) | "We assumed the blog was included." |
| 3 | Kickoff | Exclusions | "Isn't copywriting part of web design?" |
| 4 | Kickoff | Client inputs and due dates | "Why hasn't work started?" |
| 5 | Build | Revision rounds | "Just one more small change." |
| 6 | Build | Response windows and pause rule | "Why did the launch date move?" |
| 7 | Build | Change requests | "Can you add a booking system?" |
| 8 | Launch | Acceptance | "It's not finished" versus "it's done" |
| 9 | Launch | Payment schedule | "We pay when we're happy." |
| 10 | After launch | Ownership and licensing | "Send us the Figma files." |
| 11 | After launch | Support window | "The plugin update broke the form." |
| 12 | After launch | Termination and kill fee | "We're cancelling. What do we owe?" |
Governing law, limitation of liability, confidentiality and dispute resolution sit underneath all twelve. Write those with a lawyer or from a professional body's form. The twelve above are operational, and you know your projects better than any template does.
The one-sentence test for every clause
Read each clause and ask: could a third person, holding only this clause and the project's email log, decide who is right? If the answer depends on you explaining what you meant, rewrite it. "Reasonable revisions" fails the test. "Two rounds of consolidated feedback per design phase" passes.
Kickoff clauses: scope, exclusions and client inputs
Scope as an exhibit, not a paragraph
Keep the contract body short and point to a separate scope document as Exhibit A. You can then reuse the contract across projects and only rewrite the exhibit. Every line in the exhibit should carry a number, a name or a date: "up to 8 page templates", "contact form with 4 fields", "staging link by week 3". "A modern, responsive website" contains none of those and settles nothing. The web design scope document template breaks this into 12 sections with a countability audit.
Write the exclusions out
Clients rarely argue about what you listed. They argue about what you didn't mention. A short exclusions list closes most of those gaps:
- Copywriting, translation and proofreading
- Photography, illustration and stock licence fees
- Hosting, domain registration and email setup
- Migration of existing content beyond a stated number of pages
- Third-party plugin, font or app subscriptions
- Ongoing SEO, ads or analytics work after launch
Add a line saying that excluded items can be quoted separately under the change request clause. That turns "no" into a priced "yes".
Client inputs: the clause most templates skip
Look at the elements listed in Amelia's roundup of web design contract templates or Duda's suggested contract layout. Both cover scope and fees. Amelia's list doesn't address client materials directly, and Duda handles them mainly in a general notes section. Yet the client's own material is a dependency that stalls many projects. Logos, page copy, product data, logins and photos arrive late, arrive in pieces, or arrive by five different routes.
A client inputs clause names four things:
- What is required: a numbered list, ideally the same list as your intake brief.
- How it is delivered: one channel, such as a single upload link or portal, not "by email or whatever works".
- When it is due, written relative to kickoff ("within 10 business days of signing") rather than as a calendar date that breaks when signing slips.
- What happens if it's late: the timeline moves by the same number of business days, and placeholder content may be used to keep the build going.
Example wording (adapt it with your lawyer): "The Client will provide the materials listed in Exhibit B through the project upload link within 10 business days of the Effective Date. Each business day of delay moves the delivery schedule by one business day."
If your intake already runs through a structured form, attach that form as Exhibit B. The web design project intake form article sorts fields by the date each one blocks work, which maps directly onto due dates in this clause.
Build-phase clauses: revisions, response windows and changes
Count revision rounds, and define what a round is
"Two rounds of revisions" means nothing until you define a round. A workable definition: one consolidated list of feedback, sent at once, by the client's named approver. Ten separate emails from three stakeholders are not three rounds. Without the definition, they are whatever the client says they are.
Split the count by phase. A common pattern is two rounds on the design and one on the built site, since changes after build cost more. Extra rounds are billed at your stated hourly rate or quoted under the change request clause.
Response windows and the pause rule
This is the clause that explains a moved launch date before anyone asks. Take a fictional 8-week project with four approval gates: sitemap, homepage design, inner-page design, and staging review. With a 5-business-day response window at each gate, the client holds up to 20 of the project's 40 business days. Half the calendar is theirs, and the contract should say so.
The clause needs three parts:
- The window: "The Client will respond to each deliverable within 5 business days."
- The shift: delays on the client's side move the schedule day for day.
- The pause: if there is no response after a longer period, say 15 business days, the project is paused. Restarting depends on your availability, and the paused time doesn't count against your deadlines.
A contract signed in December needs one more line. Projects that run across the year-end holidays lose approval days on both sides, and the main contact is often away. Name a backup approver in clause 1, and state whether public holidays in each party's location count as business days. Writing this down in December costs one sentence. Finding out in the first week of January that nobody on the client's side can sign off costs a week.
Change requests
Anything outside Exhibit A goes through the same three steps: written request, your written estimate of cost and timeline impact, and the client's written approval before work starts. Name the format ("by email to the project address is enough") so the process doesn't feel bureaucratic. The goal is a paper trail, not a signature ceremony for every new button.
Launch clauses: acceptance and payment
Define when the site counts as accepted
Without an acceptance clause, "finished" stays an opinion. Write a short window after staging handover, for example 5 business days, during which the client sends a list of defects. A defect is something that doesn't match Exhibit A or doesn't work as described. A change is anything new. You fix defects at no cost; changes go through clause 7. If no defect list arrives in the window, the site counts as accepted. Whether such deemed acceptance holds under your law is one of the points to confirm in the legal review.
| Client says | Defect or change? | Why |
|---|---|---|
| "The contact form doesn't send." | Defect | Exhibit A lists a working form |
| "The menu breaks on mobile." | Defect | Responsive layout was in scope |
| "Can the hero be a video instead?" | Change | Not in the approved design |
| "Add a second language." | Change | Translation was excluded |
Tie payments to milestones, not to dates
Link each invoice to a deliverable so that payment follows progress. A fictional example on a project fee of 6,000 (in whatever currency you invoice) with a 40/30/30 split:
- 2,400 on signing, before the work slot is reserved
- 1,800 on design approval
- 1,800 on acceptance, due before final files and admin access are handed over
The last condition matters most: release of final files and credentials waits for the final payment. On late payment interest or fees, check what your jurisdiction allows before you write a number. Rules on rates and notice periods differ, and a fee that local law caps can weaken the clause.
Around the turn of the year, ask the client one practical question: does any invoice need to land in their current budget year? Some clients would rather pay the design milestone in December than carry it into January's budget. Putting the answer into the schedule avoids an awkward re-invoicing request later.
After-launch clauses: ownership, support and exit
Ownership transfers on final payment, and only for what you made
Who owns design work by default depends on the jurisdiction and on how the engagement is set up, so don't rely on defaults. Spell out four categories:
- Final deliverables made for this project: transfer to the client, or get licensed to them, on full payment. Some jurisdictions don't allow a full transfer of copyright and work with exclusive licences instead, so have the wording checked locally.
- Your pre-existing tools: code snippets, components and frameworks you reuse across clients. You keep these and grant the client a licence to use them on this site.
- Third-party assets: fonts, stock images, plugins and themes. These are licensed, usually to the client, under the vendor's terms. You can't transfer what you never owned.
- Working files and portfolio rights: say whether source files such as layered design files are included, and whether you may show the project in your portfolio once it's public.
A support window with a fixed end
State a period after acceptance, for example 30 days, in which you fix defects at no charge. Then list what it doesn't cover: new features, content edits, problems caused by the client's own changes, and breakage from third-party updates. After the window, support is billed or covered by a separate maintenance agreement. Leave the window open-ended and the project never closes.
Termination and the kill fee
Either side should be able to end the contract with written notice. The clause answers three questions: what the client pays for work done to date (usually measured against the milestones above), whether a kill fee applies on top, and what the client receives once paid. A fictional example: if the client cancels after design approval, they owe the first two milestones plus a kill fee of 10% of the remaining balance, and they receive the approved design files. Whether a kill fee is enforceable as written is a question for your lawyer, not a template.
Templates, Word and PDF: where each fits
Free templates are useful for one thing: the order and wording of the boilerplate. The lists collected in the Amelia roundup linked above, including AIGA's standard form, give you an established starting structure. What no template can supply is your Exhibit A, your input list, your revision definition or your response windows. Those come from how you actually run projects.
A practical split: keep the master contract as an editable Word or Google Docs file, generate a PDF for each client, and have it signed as PDF so the version is fixed. Update the master whenever a project teaches you a new clause, which in practice means after almost every difficult one. Pricing language and contract language should agree, too: setting clear pricing expectations covers the proposal side of the same problem.
A 10-point check before you send it
Score one point for each yes. Below 8, fix the gaps before the client sees the contract.
- Scope lives in an exhibit, and every line has a number, name or date.
- Exclusions are listed, with a route to quote them separately.
- Client inputs are listed, with one delivery channel and a due date relative to kickoff.
- A revision round is defined, and rounds are counted per phase.
- Response windows are in business days, with a day-for-day schedule shift.
- A pause rule names how long silence lasts before the project stops.
- A backup approver is named, which matters for projects crossing the holidays.
- Acceptance has a window and a defect-versus-change definition.
- Final files and credentials are released on final payment.
- Ownership separates final deliverables, your tools and third-party licences.
Then have a lawyer in your jurisdiction review the master once, and again when you change it substantially, rather than for every project. One review of a reusable master usually costs less than a dispute over a contract nobody checked.